TXLP Single conductor heating cablesHome > Products > Anze Heating cables Series

  • Specification
  • Installation Manual

 

17W/m Single conductor (TXLP) heating calbe Specification

 

Anze Code No. Voltage (V) Power (W) Resistence per meter(Ω) Standard Length (m) Power per meter (W/m) Total value of resistance (Ω)
AV01173100 220 3100 0.086 182 17 15.6
AV01172800 220 2800 0.105 165 17 17.3
AV01172600 220 2600 0.122 153 17 18.6
AV01172400 220 2400 0.143 141 17 20.2
AV01172200 220 2200 0.170 129 17 22.0
AV01172000 220 2000 0.206 118 17 24.2
AV01171750 220 1750 0.269 103 17 27.7
AV01171600 220 1600 0.321 94 17 30.3
AV01171400 220 1400 0.420 82 17 34.6
AV01171250 220 1250 0.527 74 17 38.7
AV01171000 220 1000 0.823 59 17 48.4
AV01170850 220 850 1.139 50 17 56.9
AV01170700 220 700 1.679 41 17 69.1
AV01170600 220 600 1.679 35 17 80.7
AV01170500 220 500 2.286 29 17 96.8
AV01170400 220 400 3.297 24 17 121.0
AV01170300 220 300 5.143 18 17 161.3
AV01170200 220 200 9.142 15.4 13 242

 

Remark:Volage:220V,Standard length is heaing area size,cold line is2.25M,remarks as below example.

Example:ANZE  TXLP/1 Nom 15.6 OHM 3100 w - 17w/m @ 220VAC 10/2003 AV01173100 CE RoHS

Heating calbes and Remarks can do OEM custom made

 

 
18.5W/m Single conductor (TXLP) heating calbe Specification
 
 
Anze Code No. Voltage (V) Power (W) Resistance permeter (Ω) Standard Length (m) Power per meter (W/m) Tota value of resistance (Ω)
AV01183150 220 3150 0.090 170 18.5 15.4
AV01183000 220 3000 0.099 162 18.5 16.1
AV01182800 220 2800 0.114 151 18.5 17.3
AV01182600 220 2600 0.132 141 18.5 18.6
AV01182400 220 2400 0.155 130 18.5 20.2
AV01182200 220 2200 0.185 119 18.5 22.0
AV01182000 220 2000 0.224 108 18.5 24.2
AV01181760 220 1760 0.289 95 18.5 27.5
AV01181600 220 1600 0.350 86 18.5 30.3
AV01181400 220 1400 0.457 76 18.5 34.6
AV01181200 220 1200 0.622 65 18.5 40.3
AV01181000 220 1000 0.895 54 18.5 48.4
AV01180850 220 850 1.239 46 18.5 56.9
AV01180700 220 700 1.827 38 18.5 69.1
AV01180600 220 600 2.487 32 18.5 80.7
AV01180500 220 500 3.587 27 18.5 96.8
AV01180400 220 400 5.596 22 18.5 121.0
AV01180300 220 300 9.949 16 18.5 161.3
 
Remark:Volage:220V,Standard length is heaing area size,cold line is2.25M,remarks as below example.
Example:ANZE TXLP/1 Nom 15.6 OHM 3100 w - 17w/m @ 220VAC 10/2003 AZV11173100 CE RoHS
Heating calbes and Remarks can do OEM custom made
 
 

TXLP/1 Series Road, Roof & Gutter De-icing Heating Cable Specification

Model

Anze Code No.

Voltage (V)

Powr(W)

Power per meter (W/m)

Standard Length (m)

Tota value of resistance (Ω)

Weight(Kg)

ADSI/1-25

AZV01251400

220

1400

25

56

34.6

4

ADSI/1-25

AZV01252600

220

2600

25

104

18.6

6.9

ADSI/1-25

AZV01253500

220

3500

25

140

13.8

9.2

Remark:

ANZE ADSI/1 Nom 13.80HM 3500w-25w/m @ 220VAC A21/05/2012 AZV01253500 CE RoHS 

     
 Structure:1、heating element:copper nickel alloy wire         2、Insulation: XLPE                 3、Sheilding layer:Aluminum-plastic composite tape     4、Grounding line:8*0.4  tinned copper wire           5、Outer jacket:90℃  Environmentally friendly flame retardant PVC       6、Cold line length:5M
 
 Color of Outer Jacekt:Blue
 Model meaning:A-ANZE      D-Defrost      S-Single      I-Insulation      1- Single conductor    2- twin conductor     25、26 -- Power per meter