TXLP Twin conductor heating cablesHome > Products > Anze Heating cables Series

  • Specification
  • Installation Manual

17W/m Twin conductor (TXLP) heating calbe Specification

 

Anze Code No. Voltage (V) Power (W) Resistence per meter(Ω) Standard Length (m) Power per meter (W/m) Total value of resistance (Ω)
AV02173300 220 3300 0.076 194 17 14.7
AV02173000 220 3000 0.091 176 17 16.1
AV02172800 220 2800 0.105 165 17 17.3
AV02172600 220 2600 0.122 153 17 18.6
AV02172400 220 2400 0.143 141 17 20.2
AV02172200 220 2200 0.170 129 17 22
AV02172000 220 2000 0.206 118 17 24.2
AV02171700 220 1700 0.285 100 17 28.5
AV02171370 220 1370 0.438 81 17 35.3
AV02171250 220 1250 0.527 74 17 38.7
AV02171000 220 1000 0.823 59 17 48.4
AV02170840 220 840 1.166 49 17 57.6
AV02170700 220 700 1.679 41 17 69.1
AV02170600 220 600 2.286 35 17 80.7
AV02170500 220 500 3.291 29 17 96.8
AV02170400 220 400 5.143 24 17 121.0
AV02170300 220 300 9.142 18 17 161.3
AV02101610 220 1610 0.187 161 10 30.1
AV02101300 220 1300 0.286 130 10 37.2
AV02101050 220 1050 0.439 105 10 46.1
AV02100940 220 940 0.548 94 10 51.5
AV02100760 220 760 0.838 76 10 63.7
AV02100530 220 530 1.723 53 10 91.3
AV02100380 220 380 3.353 38 10 127.4
AV02100230 220 230 9.148 23 10 210.4

Remark:Volage:220V,Standard length is heaing area size,cold line is2.25M,remarks as below example.

Example:ANZE  TXLP/2R Nom 14.7 OHM 3300 w - 17w/m @ 220VAC 10/2003 AZV02173300 CE RoHS

Heating calbes and Remarks can do OEM custom made

 

 

 

18.5W/m Twin conductor (TXLP) heating calbe Specification

 

Anze Code No. Voltage (V) Power (W) Resistance per meter (Ω) Standard Length (m) Power per meter (W/m) Tota value of resistance (Ω)
AV02183150 220 3150 0.090 170 18.5 15.4
AV02183000 220 3000 0.099 162 18.5 16.1
AV02182800 220 2800 0.114 151 18.5 17.3
AV02182600 220 2600 0.132 141 18.5 18.6
AV02182400 220 2400 0.155 130 18.5 20.2
AV02182200 220 2200 0.185 119 18.5 22.0
AV02182000 220 2000 0.224 108 18.5 24.2
AV02181800 220 1800 0.276 97 18.5 26.9
AV02181600 220 1600 0.350 86 18.5 30.2
AV02181370 220 1370 0.477 74 18.5 35.3
AV02181250 220 1250 0.573 68 18.5 38.7
AV02181000 220 1000 0.895 54 18.5 48.4
AV02180840 220 840 1.269 45 18.5 57.6
AV02180700 220 700 1.827 38 18.5 69.1
AV02180600 220 600 2.487 32 18.5 80.7
AV02180500 220 500 3.582 27 18.5 96.8
AV02180400 220 400 5.596 22 18.5 121.0
AV02180300 220 300 9.949 16 18.5 161.3

 

Remark:Volage:220V,Standard length is heaing area size,cold line is2.25M,remarks as below example.

ExampleANZE TXLP/2R Nom 15.4 OHM 3150 w - 18.5w/m @ 220VAC 10/2003 AZV02183150 CE RoHS
Heating calbes and Remarks can do OEM custom made

 

TXLP/2 Series Road, Roof & Gutter De-icing Heating Cable Specification

Model

Anze Code No.

Voltage (V)

Powr(W)

Power per meter (W/m)

Standard Length (m)

Tota value of resistance (Ω)

Weight(Kg)

ADSI/2-26

AZV02261400

230

1400

26

54

37.8

3.9

ADSI/2-26

AZV02262600

230

2600

26

100

20.3

6.6

ADSI/2-26

AZVO2263500

230

3500

26

135

15.1

8.9

Remark:

ANZE ADSI/2 Nom 15.10HM 3500w-26w/m @ 230VAC A21/05/2012 AZV02263500 CE RoHS

Heating calbes and Remarks can do OEM custom made

 
 Structure:1、heating element:copper nickel alloy wire         2、Insulation: XLPE                 3、Sheilding layerAluminum-plastic composite tape     4、Grounding line:8*0.4  tinned copper wire           5、Outer jacket:90℃  Environmentally friendly flame retardant PVC       6、Cold line length:5M
 
  Color of Outer Jacekt:Blue
  Model meaning:A-ANZE      D-Defrost      S-Single      I-Insulation      1- Single conductor    2- twin conductor     25、26 -- Power per meter